Table 2 Fracture loads of ECT and 6PBP tests

From: The use of ECT and 6PBP tests to evaluate fracture behavior of adhesively bonded steel/epoxy joints under Mode-III and Mixed Mode III/II

 

Test no.

ECT

6PBP (a 0  = 30 mm)

a 0  = 10 mm

a 0  = 15 mm

a 0  = 20 mm

a 0  = 25 mm

a 0  = 30 mm

Type I

Type II

Type III

Failure load (N)

1

495

505

407

373

352

910

1045

898

2

533

420

440

410

342

1140

841

935

3

502

485

443

357

260

1210

892

912

Mean value (N)

510

470

430

380

318

1087

926

915

(Std.)

(23)

(50)

(23)

(30)

(58)

(177)

(119)

(20)