From: Influence of glass-fiber reinforcement on the flexural strength of different resin composites
Composite | Flexural strength (MPa) | |
---|---|---|
Fiber | Without fiber | |
X-tra fil | 133.53 (8.80) Aa | 102.86 (6.39) Ab |
Filtek Z350 XT | 116.14 (6.62) Ba | 101.51 (6.66) Ab |
Filtek Z350 XT Flow | 104.29 (9.05) Ca | 82.70 (9.20) Bb |