Skip to main content

Table 3 Measured coaxial and angle deviations of 20 bonded specimen

From: A new joining-device for manufacturing tubular butt joints with higher curing temperatures of film adhesives

Deviation Unit Average s Min Max
Coaxial deviation mm 0.041 0.020 0.020 0.107
Angle deviation ° 0.027 0.022 0.008 0.052